Receiver mode
15 MHz real-time BW, waterfall + digital phosphor, demodulation and IQ.
KC908 is an SDR-based wide-band receiver with onboard processing and UI. It combines spectrum analysis, field strength measurement, demodulation and IQ recording in a 900 g handheld form factor.
900 g, ultra-fast sweep and standalone RF analysis.
Wide-band spectrum & field strength measurement, FM/SSB/P25/TETRA/DMR demodulation, IQ recording to micro‑SD.
Standalone SDR with integrated DSP and UI, compatible with HDSDR and GNURadio.
3 GHz/s sweep, 10 kHz resolution, less than 0.1 s for 300–500 MHz.
Signal source function for RF generation and IQ replay.
Analyze, receive, generate and correlate RF signals.
15 MHz real-time BW, waterfall + digital phosphor, demodulation and IQ.
3 GHz/s sweep, configurable RBW, list of signals of interest.
Full range RF output, AF/FM/PM modulation, 90 dB output range, IQ replay.
Compares phase and amplitude of two input channels (KC908A/B).
Automatic RBW and accurate frequency results at any span up to 18.6 GHz.
Peak list records frequency and POI of detected signals.
Play IQ file record by KC908 or import files to Micro SD card, also can set amplitude and replay frequency. This is a useful feature for testing digital systems.
The KC908B has the most powerful signal source in the series, with a maximum output amplitude of +10dBm 18GHz and a synchronous tuning filter.
RF signal output covering the entire frequency range, supporting AM/FM/PM modulation modes, 90dB amplitude setting range. Most importantly, IQ replay is supported!
Only in KC908A/B models.
Compare the amplitude and phase difference of two port input signals.
With professional and precise hardware design, high performance is realized in a very small volume, and strict RF front-end design, even the weakest signals can be detected under the strong interference field.
KC908 has a built-in multi band Pre-filter that automatically switches to the current operating frequency.
| Item | Min | Typical | Max | Note |
|---|---|---|---|---|
| Frequency range | 100 kHz | 4/6/10.8/18.6 GHz | ||
| Real time bandwidth | 1 kHz | adjustable | 15 MHz | |
| Analysis bandwidth | 1 Hz | adjustable | 2 MHz | up to 8 MHz |
| Demodulation bandwidth | 150 Hz | adjustable | 300 kHz | |
| 100% POI (note 3) | 210 us | SPAN=15 MHz | ||
| Level measurement range | +20 dBm | |||
| Level measurement uncertainty | 1.5 dB | Receiver mode | ||
| Noise floor | -120 dBm | @12 kHz BW, avg | ||
| Normalized noise floor | -163 dBm/Hz | Max Gain, avg | ||
| Instrument noise coefficient | 13 dB | Max Gain | ||
| Third-order intercept point | -42 dBm | 46 dBm | REF = -70 dBm | |
| First image suppression | 50 dB | 70 dB | REF = 20 dBm | |
| IQ image suppression | 60 dB | |||
| Residual response (note 4) | -110 dBm | Port N.C | ||
| Spurious response | -90 dBm | With Whip Antenna | ||
| Signal generator output level (note 5) | -80 dBm | 10 dBm | 1 dB Step | |
| Battery life | 4 h | |||
| Weight | 900 g |